beautypg.com

Chapter 2 - specifications, A brief description of chapter 2, Modes of operation – Hardy HI 1746-WS User Manual

Page 17: Conversion rate, Averages, Resolution, Input, Non-linearity, Maximum zero tolerance, Waversaver

background image

Chapter 2 - Specifications

2-1

CHAPTER 2 - SPECIFICATIONS

A Brief Description of
Chapter 2

Chapter 2 lists the specifications for the HI 1746-WS
Weigh Scale Module. Specifications are listed for the
standard instrument and for optional equipment. The
specifications listed are designed to assist in the
installation, operation and troubleshooting of the
instrument. All service personnel should be familiar
with this section before attempting an installation or
repair of this instrument.

Specifications for a
Standard HI 1746-WS
Weigh Scale Module

Modes of
Operation

Local and Remote

Conversion Rate

20 updates per second

Averages

1-255 User Selectable in single increments

Resolution

Displayed:

1:985,000 (@ 3 mV/V)
1:656,000 (@ 2 mV/V)

Internal:

1:1,048,576

Input

Up to eight (8) 350 ohm Full Wheatstone Bridge,
Strain Gauge Load Sensors/Cells (5 volt excitation)
on one vessel.

Non-Linearity

0.0015% of Full Scale

Maximum Zero
Tolerance

32766

WAVERSAVER

®

User Selectable

7.50 Hz

3.50 Hz

1.00 Hz (Default)

0.50 Hz

0.25 Hz

Excitation Monitor

Current less than +/- 10% expected