Executable command list, Zero command (zerocmd), Tare command (tarecmd) – Hardy HI 1746-WS User Manual
Page 40: Executable command list -10

HI 1746-WS WEIGH SCALE MODULE
4-10
Executable Command
List
CAUTION:
ALWAYS PERFORM A READ COMMAND
FIRST BEFORE THE WRITE COMMAND
EVERYTIME, TO GET THE CORRECT
SEQUENCE NUMBER. (SEE THE SET-
PARAMS EXAMPLE, RUNG 0 FOR THE LAD-
DER LOGIC)
Zero Command
(ZEROCMD)
The Zero Command requests that the current gross
weight be set to zero.
Error Return Values:
•
NOTALLOWED - the ZeroEnable parameter is
not set to TRUE (1),
•
OUTOFTOLERANCE - the current weight value
is beyond the limits set by the zero tolerance
parameter.
•
“STATUSWORD” - the command failed because
the weight was not stable (in motion), or that
there was an A/D error of some kind.
SEQ
NUMBER
0
COMMAND#
(Hex)
1
STATUS
2
OFFSET
3
LENGTH
4
DATA
5-16
From M1 File
1
Tare Command
(TARECMD)
The Tare Command requests the current net weight be
set to zero.