9 repairs, 1 checklist for troubleshooting, Repairs 9.1 checklist for troubleshooting – FRITSCH PULVERISETTE 19 User Manual
Page 51: 9repairs, Repairs
9
Repairs
DANGER!
Mains voltage!
– Before beginning with repair work, unplug the mains
plug and protect the device against being unintention-
ally switched back on.
– Indicate repair work with warning signs.
– Repair work may only be performed by specialised per-
sonnel.
– Put safety equipment back into operation after mainte-
nance work.
9.1 Checklist for troubleshooting
Fault description
Cause
Remedy
Start button does not light up
green
No mains connection
Plug in mains plug (20)
The control switch (19) is at 0
Set the control switch (19) to AUTO or HAND
Incorrect direction of rotation
Reverse two phases (Ä Chapter 4.7 ‘Electrical
Socket fuse is faulty
Check socket fuse
Device fuse blown
Remove the housing and replace the fuse
START button is pressed but
mill does not start up
Closing lid (6) not closed prop-
erly
Clean contact surface, close closing lid (6)
Collecting vessel (8) or adapter
for exhaust system (27) not
inserted properly
Insert collecting vessel (8) or adapter for exhaust
system (27) properly ® until safety switch (15)
engages.
The control switch (19) is set to
HAND.
Switch the control switch to AUTO.
Coarse samples were added to
the machine first and are
blocking rotor start-up.
Open grinding chamber and remove sample
material. ® Switch on device before adding
sample.
Mill stops running
Motor safety switch has trig-
gered
Motor safety switch (see Ä Chapter 6.4 ‘Over‐
load of the cutting mill’ on page 37)
STOP button lights up red
Incorrect direction of rotation
Swap two phases in the mains plug (20)
(Ä Chapter 4.7 ‘Electrical connection’
Too much comminution material
in grinding chamber
Reduce feeding amount
Repairs