Use stored sample alignment lock value, Use default sample alignment lock value – Aviom 6416o User Manual
Page 51
42
o
PerAtiNg
s
Ystem
u
PdAte
is changed, or when the system configuration changes. (Changes include the
addition/subtraction of Pro64 modules, different wiring schemes, etc.)
Use Stored Sample Alignment Lock Value
When a new sample alignment lock value has been generated and stored,
Function 13 can be used to activate and lock in this value for use throughout
the network. This Function can only be performed at the Control Master
when the network is unlocked.
To use the stored value, press the
F
unCtion
button, followed by the
C
hannEl
13
aCtivE
button. The Enter/Cancel LED and the sixteen yellow channel meter
LEDs will flash. Press
E
ntEr
to use the stored value, or press
C
anCEl
to exit
without changing the sample alignment value (the system reverts to using
the default value).
The stored sample alignment value remains in force even when the network
is power cycled. When the network is reconfigured or when the sample rate
is changed, a new value should be calculated.
Use Default Sample Alignment Lock Value
The system calculates a sample alignment lock value to be used as the
default every time the network is powered up, or when the sample rate is
changed. Function 14 can be used at the Control Master to set the network
to use the default value. (Function 13 is used to instruct the system to use a
stored value. )
To set the network to use the default sample alignment value, press
F
unCtion
,
followed by the
C
hannEl
14
aCtivE
button. The sixteen yellow channel meter
LEDs and the Enter/Cancel LED will flash. Press
E
ntEr
to use the default value,
or press
C
anCEl
to exit without changing the current value.
Use Function 11 (Get Sample Alignment Info) to display the current value in
use—default or stored.