Rate/format, Tc input – 360 Systems TCR Multi-Track User Manual
Page 101

TCR Series User's Guide
Machine Setup 5-17
Rate/Format
MENU | Machine Setup | Sync and Time Code | Rate/Format
The Rate/Format function allows you to set the TCR’s frame rate and sample rate. Use the
following steps to set the sample and frame rates:
1. On the Setup Sync and Time Code Menu, select item 1 (RATE/FORMAT). The current
settings are highlighted.
2. Select the desired rates. Ten choices are available.
•
30N 48000: 30 fields per second frame rate, non-drop frame, 48000 Hz sample rate.
•
30D 48000: 30 fields per second frame rate, drop frame, 48000 Hz sample rate.
•
30N 48048 (VID/LTC): 30 fields per second frame rate, non-drop frame, 48048 Hz
sample rate. The format is valid only when Sync Ref is set to VIDEO and TC Input
is set to LTC. Audio recorded at this pulled-up sample rate can be played back at
29.97N 48000, keeping the same number of samples per frame.
•
30D 48048 (VID/LTC): 30 fields per second frame rate, drop frame, 48048 Hz
sample rate. The format is valid only when Sync Ref is set to VIDEO and TC Input
is set to LTC.
•
29.97N 48000: 29.97 fields per second frame rate, non-drop frame, 48000 Hz
sample rate.
•
29.97D 48000: 29.97 fields per second frame rate, drop frame, 48048 Hz sample
rate.
•
29.97N 47952 (VID/LTC): 29.97 fields per second frame rate, non-drop frame,
47952 Hz sample rate. The format is valid only when Sync Ref is set to VIDEO and
TC Input is set to LTC. Audio recorded at this pulled-down sample rate can be
played back at 30N 48000, keeping the same number of samples per frame.
•
29.97D 47952 (VID/LTC): 29.97 fields per second frame rate, drop frame, 47952
Hz sample rate.
•
25 FPS 48000: 25 fields per second frame rate, 48000 Hz sample rate.
•
24 FPS 48000: 24 fields per second frame rate, 48000 Hz sample rate.
TC Input
MENU | Machine Setup | Sync and Time Code | TC Input
The TC Input function allows you to select a time code input for use as a positioning indication —
specifically for use in the “Chase Mode.”
Use the following steps to select the time code input:
1. On the Setup Sync and Time Code Menu, select item 2 (TC INPUT). The current setting is
highlighted.
2. Select the desired positioning indication.
•
LTC: the LTC port is used. A valid LTC signal must be present.
•
VITC: the VITC port is used. A valid VITC signal must be present.