Table 4.6

ICKDSF Commands for 9900 Contrasted to RAMAC

Command Argument

Subsystem

Return

Code

INSPECT

KEEPIT

RAMAC

CC = 12 Invalid parameter(s) for device type.

9900

CC = 12, F/M = 04 (EC=66BB).

PRESERVE

RAMAC

CC = 4 Parameter ignored for device type.

9900

CC = 12, F/M = 04 (EC=66BB) Unable to establish primary and

alternate track association for track CCHH=xxxx.

SKIP

RAMAC

CC = 4 Parameter ignored for device type - skip.

9900

CC = 12, F/M = 04 (EC=66BB) Primary track

CCHH-xxxx found unrecoverable.

NOPRESERVE,

NOSKIP,

RAMAC

CC = 0, ALT information not displayed.

NOCHECK

9900

CC = 0

ALLTRACKS,

ASSIGN,

RECLAIM

RAMAC

CC = 12 Invalid parameter(s) for device type.

9900

In case of PRESERVE: CC = 12,

In case of NO PRESERVE: CC = 0.

INSTALL

SETMODE (3390)

RAMAC

CC = 0 (but not recommended by IBM).

9900

CC = 0

SETMODE (3380)

RAMAC

CC = 12, Invalid parameter(s) for device type.

9900

CC = 12, Function not supported for nonsynchronous DASD.

ANALYZE

RAMAC

CC = 0

9900

CC = 0

BUILDX

RAMAC

CC = 0

9900

CC = 0

REVAL

REFRESH

RAMAC

CC = 12 Device not supported for the specified function.

9900

CC = 12, F/M = 04 (EC=66BB) Error, not a data check.

Processing terminated.

DATA,

NODATA

RAMAC

CC = 0, Data/Nodata parameter not allowed.

9900

CC=0

CONTROL

RAMAC

CC = 0, ALT information not displayed.

9900

CC = 0, ALT information not displayed.

INIT

RAMAC

CC = 0, ALT information not displayed.

9900

CC = 0

REFORMAT

RAMAC

CC = 0, ALT information not displayed.

9900

CC=0

CPVOLUME

RAMAC

CC = 0, Readcheck parameter not allowed.

9900

CC=0

AIXVOL

RAMAC

Readcheck parameter not allowed.

9900

CC = 0