5.6 Channel Specifications and Requirements

Table 5.15 lists the ESCON

®

and FICON™ port specifications for the 9900, and Table 5.16 lists

the fibre-channel port specifications for the 9900. Each 9960 subsystem supports up to four
channel adapters and 32 interface ports. Each 9910 subsystem supports up to three channel
adapters and 24 interface ports. Each adapter consists of two cards.

Note: The 8GSE and 8HSE ports are applicable for Hitachi TrueCopy – S/390

®

.

Note: Additional power supplies are needed if three or more channel adapters are installed.

Table 5.15 ESCON

®

and FICON™ Port Information

ESCON

®

Ports

FICON™ Ports


Item

ExSA™
4-Port

ExSA™
8-Port

4-Port
SW

4-Port
LW

Adapter model number

4S

8S

4MS

4ML

Max. data transfer rate (MB/s) 10/17

10/17

100 (1 Gbps) 100 (1 Gbps)

Number of ports/adapter

4

8

4

4

Number of MPs/adapter

4

8

4

4

Host interface

ExSA™ ExSA™

FICON™

FICON™

Number of adapter pairs per

9960 subsystem

1 to 4

1 to 4

1 to 4

1 to 4

Number of adapter pairs per

9910 subsystem

1 to 3

1 to 3

1 to 3

1 to 3

Max. interface cable length

43 km

43 km

500 m

*1

10 km

*1. Indicates when 50 / 125

µm multi-mode fiber cable is used. If 62.5 / 125 µm multi-mode fiber cable is used,

maximum length decreases to 300 m.

Table 5.16 Fibre-Channel Port Information

Fibre-Channel Ports


Item

4-Port
SW

8-Port
SW

4-Port
LW

8-Port
LW

2 Gbps
8-Port SW

Adapter model number

4GS 8GS/GSE

4GL 8GL 8HSE

Max. data transfer rate (MB/s) 100

(1 Gbps)

100

(1 Gbps)

100

(1 Gbps)

100

(1 Gbps)

100/200

(1/2 Gbps)

Number

of

ports/adapter

4 8 4 8 8

Number

of

MPs/adapter

4 8 4 8 8

Host

interface

FC FC FC FC FC

Number of adapter pairs per

9960 subsystem

1 or 4

1 to 4

1 to 4

1 to 4

1 to 4

Number of adapter pairs per

9910 subsystem

1 or 3

1 to 3

1 to 3

1 to 3

1 to 3

Max. interface cable length

500 m

*1

500

m

*1

10 km

10 km

500/300 m

*2

*1. Indicates when 50 / 125

µm multi-mode fiber cable is used. If 62.5 / 125 µm multi-mode fiber cable is used, maximum length

decreases to 300 m.

*2. Indicates when 50 / 125

µm multi-mode fiber cable is used. If 62.5 / 125 µm multi-mode fiber cable is used, 500 m (100

MB/s) and 300 m (200 MB/s) decrease to 300 m and 150 m, respectively.