4 trap table, 1 adding or editing a trap manager – CANOGA PERKINS 9145ELB NID Software Version 4.01 User Manual
Page 31

System Configuration
9145ELB NID Software User’s Manual
IP/SNMP Agent Configuration
21
3.1.4 Trap Table
On the IP/SNMP Agent Configuration screen (Figure 3-4), type 4 and press Enter. The Trap
Notification Destination Table screen (Figure 3-9) opens.
The Trap Table screens are used to configure the SNMP Trap Managers.
Figure 3-9 Trap/Notification Destination Table screen
3.1.4.1 Adding or Editing a Trap Manager
1. To add a Managing Host IP address, from the Trap Notification Destination Table screen
(Figure 3-9), type A and press Enter (to edit, type E and press Enter). The Edit Trap
Notification Type screen open (Figure 3-10)
2. Type the Managing Host IP address and press Enter.
3. Type the Trap/Notification Port and press Enter.
The default value is 162 for regular SNMP managers (163 for CanogaView). Any port
numbers from 1 to 65535 can be used to receive traps. Check with your IT manager to
ensure the port setting is correct.
Canoga Perkins Corp. Ethernet 1G/10G Network Interface Device 29-AUG-2011
9145ELB-971-4-0 V04.01 10:55:13
---------------------TRAP/NOTIFICATION DESTINATION TABLE-----------------------
Managing Trap Username/ Security
Host Port Type Community Level
Select [(A)dd, (D)elete, (E)dit, (M)ore]:
------------------------------------Messages-----------------------------------