CANOGA PERKINS 9145ELB NID Software Version 4.01 User Manual
Page 25

System Configuration
9145ELB NID Software User’s Manual
IP/SNMP Agent Configuration
15
•
Untagged (default): Management PDUs are transported without a VLAN tag.
•
S-Tagged: Management PDUs are encapsulated by an S-Tag.
•
S-T Tagged: Management PDUs are encapsulated by an outer S-Tag and an
inner T-Tag.
•
S-C Tagged: Management PDUs are encapsulated by an outer S-Tag and an
inner C-Tag
.
•
S-T-C Tagged: Management PDUs are encapsulated by an outer S-Tag, a middle
T-Tag, and an inner C-Tag.
NOTE: For the Mgmt UTP Port, only Untagged or C-tagged is allowed.
4. Manager C-VLAN ID If Manager VLAN Tagging is set to S-C Tagged or S-T-C Tagged,
you can set the C-VLAN Tag ID between 1 and 4094.
5. Manager T-VLAN ID If Manager VLAN Tagging is set to S-T Tagged or S-T-C Tagged,
you can set the T-VLAN Tag ID between 1 and 4094.
6. Manager S-VLAN ID If Manager VLAN Tagging is S-Tagged, S-T Tagged, S-C Tagged, or
S-T-C Tagged, you can set the S-VLAN Tag ID between 1 and 4094.
CAUTION: The Manager IP Address, Subnet Mask, and Gateway address can be
changed when locally or remotely connected. When you change the Management IP Con-
figuration via remote access, you will be automatically disconnected when the Gateway
address is changed. You will need to reconnect using the updated Manager IP Address, Subnet
Mask, and Gateway address.
NOTE: The TPIDs for the S-Tag and T-Tag are configured at a system level. See the section “S-
TPID/T-TPID Configuration” on page 123 to configure the S-Tag and T-Tag TPIDs.
DA
SA
IP Header
Management PDU
FCS
DA
SA
S-Tag
IP Header
Management PDU
FCS
DA
SA
S-Tag
T-Tag
IP Header
Management PDU
FCS
DA
SA
S-Tag
C-Tag
IP Header
Management PDU
FCS
DA
SA
S-Tag
T-Tag
C-Tag
IP Header
Management PDU
FCS