Pressurizing and balancing the pedestal, Pressurizing the pedestal, Pressurizing and balancing the pedestal –12 – Vinten Radamec SP-2000 Pedestal User Manual
Page 52: Pressurizing the pedestal –12

SP-2000/X-Y
Installation
3-12
User Manual
Pressurizing And Balancing The Pedestal
It is recommended that three people be available for this procedure.
DANGER: STRICT ADHERENCE TO THESE PROCE-
DURES IS CRITICAL IN ORDER TO AVOID ANY
BODILY INJURY TO PERSONNEL. ALL PERSONNEL
WORKING ON OR NEAR THE PEDESTAL MUST BE
TRAINED, AWARE OF THE CORRECT PROCEDURES AND AWARE
OF THE HAZARDS INVOLVED.
DANGER: THE MAXIMUM CYLINDER PRESSURE IS
1,250 PSI (86 BAR).
USE ONLY THE VINTEN SUPPLIED MANIFOLD FOR
ADJUSTING PRESSURE.
Pressurizing The Pedestal
1.
Make sure that the column locking pins are NOT installed - this will allow
the column to rise as the pressure is increased.
Fill Valve
(1 of 3)
4” Extension
Purge Valve
From Regulator
And Tank
T Valve
Fill Hose
Fill Switch
(Older
Pedestals)