Vinten Radamec Fusion Camera Control Unit (CCU) User Manual
Camera control unit
Table of contents
Document Outline
- All rights reserved throughout the world. No part of this document may be stored in a retrieval system. transmitted, copied or reproduced in any way including, but not limited to, photocopy, photograph, magnetic or other record without the prior agre...
- Vinten Radamec® and Vinten® are registered trademarks of the Vitec Group plc.
- Information contained in this document is subject to change. Camera Dynamics Limited reserves the right, without notice, to make changes in equipment design or performance as progress in engineering, manufacturing or technology may warrant.
- Out of the box
- Mounting the Fusion CCU into a rack
- Cabling
- Changing the Channel IP address
- 1. Connect a standard RS-232 serial cable from the serial port on a PC (COM1) to the CONFIG port on the rear panel of the Fusion CCU.
- 2. On the PC, launch Hyper Terminal. Ensure the HyperTerminal settings are: 9600, 8, None, 1, None.
- 3. On the rear panel of the Fusion CCU, locate the Configuration DIL switch on the rear panel. Ensure all the switches are in the up position (OFF) except for the switch that corresponds to the channel to be configured, which should be in the down po...
- 4. Reset the channel to be configured by pressing the reset switch accessible through the small hole in the rear panel. The reset switch is located below the ETH port and to the left of the RS-232 LED for the channel.
- 5. Observe that the corresponding Channel LED is illuminated on the front panel, for example if channel 2 is being configured, the orange LED under CHANNEL 2 on the front panel will illuminate.
- 6. Observe on the HyperTerminal that the configuration settings have appeared (Figure 1). Make a note of the MAC address and ensure that there is no duplication of MAC addresses.
- Figure 1 Hyper terminal window
- 7. At the prompt type “Y” then press the ENTER key. Proceed following the Hyper terminal prompts and change the channel address as required. The Local IP address must be unique for each module:
- 8. With the above changes made, check that the read-back is correct and type “n” and then press ENTER. HyperTerminal should report “Starting the main application”. Check that the Channel LED on the front panel of the Fusion CCU is not illumin...
- 9. With the channel IP address now set, return the Configuration DIL switch for the channel to the up position (OFF).
- 10. Reset the channel configured by pressing the reset switch accessible through the small hole in the rear panel.
- 1. Switch power off and remove power cable.
- 2. Disconnect all cables from the Fusion CCU rear panel.
- 3. Remove the Fusion CCU from the 19 inch rack.
- 4. With the Fusion CCU placed onto to a work bench or table, remove the four screws securing the lid. Lift off the lid and place to one side.
- 5. Place the unit upside-down on a worksurface and remove the three screws securing the rear panel. Do not disconnect any internal cabling to the channel connections (ETH and PORT).
- 6. Remove the blanking plate from the channel position. Remove the screws located on the outside of the rear panel securing the blanking plate. Remove the blanking plate.
- 7. Plug in the new channel module. Carefully align the pins, ensuring that the pins do not bend or flex the module PCB.
- 8. Fit the 9 way D connector to the back panel. Feed the D connector through the slot in the rear panel from inside the Fusion CCU. Secure the connector into position using the screw jack, nut and washer.
- 9. Plug the cable connector into the 10 way header.
- 10. Ensure the gold shunt, located next to the 10 way header, is in position and secure.
- 11. Replace the rear panel and top cover.
- 12. Configure the IP address for the newly installed channel (module) following the process outlined in Changing the Channel IP address.
- 13. Install the Fusion CCU into the 19 inch rack and secure into position. Refit all cables and install the cables for the new channel (module).
- Routine checks
- Changing the fuse
- 1. Switch OFF power to the Fusion CCU.
- 2. Carefully insert a small blunt screwdriver or similar tool into the side of the fuse compartment and lever out.
- 3. Lift out the fuse compartment.
- 4. Replace the failed fuse and then replace the fuse compartment, pushing firmly into place.
- 5. Switch ON power to the Fusion CCU. Ensure the Power ON/OFF switch illuminates and that the PSU1 and PSU2 LEDs illuminate.