Print codes and descriptions – Rice Lake DWM-IV Weighmeter Standard Operators Manual User Manual
Page 51

total of eighty (80) codes may be entered. It is possible to print out particular
headers or titles by using the ASCII representations for them in decimal.
Entering Print Codes
1. first enable under F4.7 and/or F4.8.
2. Under F3.8 of the SET-UP procedure, enter the preamble and postamble data, if
needed.
3. After the postamble step the weight data codes are entered. The display will show
the following:
xx.yyy
where xx is the code count and yyy is the print code in decimal. to enter a new
code, use the numeric keypad. Press [ENTER] to store the code and advance to the
next one. Press [ENTER] without pressing any numeric buttons to retain the
existing data. Terminate the codes with a value of 255 and [ENTER]. The display
will blink momentarily.
4. Enter the codes for the totals print-out using the same method described above
for the weight codes. Remember to always terminate the codes with value 255. Any
number greater than 255 will be ignored and the previous data will be re-displayed.
Print Codes and Descriptions
For the following table, refer to the Data Output Formats (referred to as D.O.F.)
and SET-UP procedure sections of this manual.
Code
Descriptions
128 Inserts ASCII STX and up to three (3) bytes of preamble codes, as set in step F3.8
of set-up procedure.
129 Formats weight data as described in D.O.F. Type is selected in Step F4.5 of SET-
UP procedure.
130 Formats time and date data as programmed in Step F4.6 of SET-UP.
131 Formats the ID number entered using Function 7 from the front panel. Must be
enabled under F3.5.
132 Formats the consecutive number. Must be enabled under Step F3.4.
133 Formats the total or subtotal data and register number as described in D.O.F.
134 Prints the total register number currently selected (zero to nine).
135 Internal code for carriage return-line feed. Do not use.