How to Enter and Exit System Setup
Locate the small dip switch block in the lower right corner of the mother board. Turn on
S1, the display should then show FSE F1.
From the FSE Fn display you may scroll forwards and backwards using the [TARE] and
[ZERO] buttons. When the page you want is displayed, press [PRINT] to accept and view
the first step in that page.
Example: If the setup switch S1 is turned on, the display will show FSE F1. Press
[ZERO] button. The display will show FSE F6, press [PRINT], display will show F6.0 n.
You may now change the current setting for F6.0 by pressing [TARE], accept the setting
by pressing [PRINT], or backup to F5.9 by pressing [ZERO].
You may also go directly to the page you wish to change by pressing the page number
minus 1 on the keypad, after S1 is turned on. (Example: Operate S1. Display shows FSE
F1. Press 3. Display shows FSE F4.)
Upon completion of your changes you may exit and save without having to go all the way
to the end of the setup steps by pressing the [F1] button (on most units this will be an
unlabeled button under [RECALL/TARE], second down from the top, on the right hand
side). The display will go to FCd0. Press [PRINT] to save changes or press [TARE] to
change option to 1 or 2. Option 1 will discard all changes you have made (you can also
do this by turning off S1 at any time before the display shows FILEd. Option 2 (not
available on earlier software) is used to reset the factory defaults into the EEPROM
where all of the setup data is stored (U14 under the A/D board.).
Once you have selected which FCd option to use (usually 0 which is how it comes up
automatically) save your selection by pressing [PRINT] after about a second the display
should read FILEd, at this time you may turn off the setup switch S1 and return to the
weighing mode.
Function Select Enable Descriptions
:
F1 Contains settings that control the overall operation of the scale, such as averaging,
update rate, motion detection, zero tracking, etc.
F2 Tare functions, setpoint options & powerup options are set here.
F3 Serial port parameters, enabling of print fields, and custom formatting.
F4 Serial data output formats, modes.
F5 Enables individual right hand keyboard functions.
Page 17