46
Installation and Operation Manual
4.49 Remote Totalizer Reset Input
This parameter defines a digital input bit that can be
used to reset the reset totalizer. This only affect the
reset totalizer and not the master totalizer. The master
totalizer can only be reset through the supervisor
menu.
The default value of this parameter is: 0.
4.50 Integrator Identification
The integrator ID can be an alpha-numeric string up to
8 characters.
Press the
enter
key and enter the identification ID and
press the
enter
key again to save this ID.
It can be used for printing or streaming information
using the token
4.51 Preact Length
This parameter is used to dynamically adjust the target
value based on the rate of the belt scale.
Enter the distance from the feed gate to the midpoint
of the weigh idler and the first dual idler. Enter the
preact length in feet and press the
enter
key to save
that parameter.
4.52 Enable Batching
Set to On to enable batching When enabled, the
system can control gates for filling applications.
When enabled, the operator will see
Start Fill
and
Target
Settings
softkeys on the display.
The default value is Off.
4.53 Analog 1 Mode
This parameter defines what the optional analog
output #1 tracks.
Three settings are available with this parameter. They
are:
•
Rate - Tracks to the maximum rated
c a p a c i t y o f t h e b e l t s c a l e ( s e e
Section 4.2).
•
Load - Tracks to the maximum total cell
build of the system (see Section 4.4)
•
Speed - Tracks to the maximum speed
value (see Section 4.37)
4.54 Analog 2 Mode
This parameter defines what the optional analog
output #2 tracks.
Three settings are available with this parameter. They
are:
•
Rate - Tracks to the maximum rated
c a p a c i t y o f t h e b e l t s c a l e ( s e e
Section 4.2).
•
Load - Tracks to the maximum total cell
build of the system (see Section 4.4)
•
Speed - Tracks to the maximum speed
value (see Section 4.37)
4.55 Master Totalizer Reset
To reset the Master Totalizer, press the
Master Totalizer
softkey from the Supervisor Mode to access this
parameter. The integrator prompts
Clear Master
Totalizer
?
No
SCALE #1
Yes
11/23/2011
08:13AM
Admin. Passcode (numeric)
Rate Unit Time
Speed Unit Time
Unit of Measure
Unit of Rate
Rate Count By
Totalizer Count By
Load Display Units
Load Count By
Calibration Weight
Hr
Sec
M
kg
0.1
0.1
lb
0.1
20.0
Clear Master Totalizer?
Press
Yes
to clear the totalizer or
No
to leave the
accumulated weight in the master totalizer.