5 electronic integrator, 2 operation, 1 zero – Rice Lake BCi Belt Scale - Installation and Operation Manual Version 2.03 User Manual
Page 13: 2 print, 3 reset totalizer, 4 diagnostics, 5 supervisor mode, Electronic integrator, Zero, Print
Installation and Operation Manual - Introduction and Overview
7
1.1.5
Electronic Integrator
Outputs from the belt travel speed sensor and from the load cell carriage are combined in the integrator to
produce a running total of material passed over the belt conveyor scale. Using the integrator HMI as a calibrated
electronic integrator allows signals to be converted into values that represent the weight and speed of the material
that is traveling on the conveyor.
1.2
Operation
The integrator front panel, shown below consists of a 27-button keypad with a large backlit LCD display. The
keys are grouped as five configurable softkeys, five primary scale functions keys, four navigational keys, and
numeric entry keys. It should be noted that the scale parameters and calibration values cannot be changed
without first pressing the
TARE
key and unlocking the parameters. After pressing the
TARE
key, press
enter
to
unlock the settings. Pressing
ZERO
when the display is on the main menu will clear the
Reset Total
.
UNITS
SOFTKEY1 SOFTKEY2 SOFTKEY3 SOFTKEY4 SOFTKEY5
Figure 1-6. integrator Front Panel
The following sections describe the front panel key operation of the belt scale integrator.
1.2.1
Zero
This parameter will initiate the front panel zero mechanism. Periodic use of the zero parameter is required due to
weather conditions.
1.2.2
This will print the custom ticket if the print port is configured.
1.2.3
Reset Totalizer
Often during this operation of a belt scale, the totalizer will need to be reset. This is known as the reset totalizer.
Press the
Reset Totalizer
softkey to access this parameter. The integrator will prompt the user, “
Clear Totalizer
?” The
operator will press
Yes
to clear the totalizer, or
No
to leave the accumulated weight in the totalizer.
1.2.4
Diagnostics
This softkey displays the current mV input, PPS (pulses per second from the speed sensor), current analog output
(if installed), current A/D counts, and the master total. This is just informational data that the operator or a
technician can use from troubleshooting purposes.
1.2.5
Supervisor Mode
Use this softkey to enter the Supervisor Mode. If there is no passcode configured the integrator will enter into the
Setup Mode. If a passcode is configured, the operator will need to enter the passcode before the integrator will
switch to the Supervisor Mode. To configure a passcode, see the Supervisor’s Parameters.