40 speed alarm bit, 41 totalizer pulse bit, 42 fill output bit – Rice Lake BCi Belt Scale - Installation and Operation Manual Version 2.03 User Manual
Page 51: 43 remote print input bit, 44 print output port, 45 print format, 46 stream output port, 47 stream format, 48 clear totalizer with print, 40 speed alarm bit 4.41 totalizer pulse bit
Installation and Operation Manual - Supervisor Mode Parameters
45
4.40 Speed Alarm Bit
This parameter defines which digital output bit will
activate for the high speed alarm, which is determined
by the maximum speed value settings.
The default value for this parameter is: 0.
Note
When an alarm bit (Sections 4.38, 4.39,
and 4.40) is set to 0, the alarm
becomes disabled.
4.41 Totalizer Pulse Bit
This parameter defines the digital output bit for the
totalizer pulse output.
The default value for this parameter is 2.
4.42 Fill Output Bit
This parameter defines the digital output bit used for the
fill output, the default value for this parameter is 1.
4.43 Remote Print Input Bit
This parameter defines which digital input bit will
work the same as the Print key on the front of the
integrator.
The default value for this parameter is: 4.
Note
I/O Note - There are six onboard I/O bits
on the integrator. Depending on their
use, the installer may need to
reconfigure the use to “OUTPUT” OR
“PROGIN.”
If the use is as a remote button supported by the
integrator software, the setting will be PROGIN. If it’s
used as one of the alarm bits, then OUTPUT is the setting.
4.44 Print Output Port
This parameter defines which serial port the print
format will be sent from.
The default value for this parameter is: 0.
4.45 Print Format
This parameter defines the format of the printed
output when the
key is pressed, or a KPRINT
EDP command is received. The format is made up of
tokens and other characters. Tokens are enclosed in
less than (<) and greater than (>) signs, and during the
printing process, are replaced with the value they
represent. Any characters not defined as tokens are
printed as they are. To edit, press the
Enter
key, edit
the format, then press the
Enter
key again to save.
The default printer format is:
TIME:
< M T > < N L > R E S E T T O TA L : < RT > < N L > R AT E :
The default printer format will print something like
this the following example:
TIME: 03:07PM
DATE: 06/27/2013
MATER TOTAL: 75.6
RESET TOTAL: 72.1
RATE: 143.5
TN
/
HR
Available print tokens are:
Table 4-1. Available Print Tokens
Token
Description
Rate with units
Speed with units
Load with units
Reset totalizer
Master totalizer
Integrator Identification
Reset totalizer units
Master totalizer units
New line
Time
Date
Time and date
Date and time
ASCII carriage return
ASCII line feed
ASCII form feed
4.46 Stream Output Port
This parameter defines which serial port the stream
format will be sent from. The integrator will only
stream if this is set to a valid port with a value greater
than zero.
The default value for this parameter is: 0.
4.47 Stream Format
This parameter defines the format of the stream (or
continuous) serial output. The format is made up of
token (the same tokens as the print format) and other
characters. To edit, press the Enter key, edit the
format, then press the Enter key again to save it.
The default value for this parameter is:
The default stream will continuously output the rate
value only.
4.48 Clear Totalizer with Print
Toggles between Yes and No.