Balance connector wiring, S. see, 6s pack – ProgressiveRC 6 PowerLab User Manual
Page 61
Balance connector wiring
When using FMA Wiring mode (Factory Default Setting)
The following diagrams shows how a 9 pin Cellpro (JST PA series) balance connector
(REVO PN CPBP9P-10-US) must be wired to a 6s, 5s, 4s, 3s, 2s, and 1s battery pack
when the PowerLab 6 is set to FMA Wiring mode (Factory default). Whether the
following is accomplished via the available adapters, or by physically connecting
(soldering) the 9 pin Cellpro pigtail to a battery pack directly, this is what the PowerLab
must see at its balance connector (output):
Pin 1
Red
Black
Node 5
Pack positive
Node 4
Node 3
Node 2
Node 1
Pack negative
6s Pack
Pack positive
(red), 22.2V*
Node 4, 14.8V*
Node 5, 18.5V*
Node 3, 11.1V*
Node 2, 7.4V*
Node 1, 3.7V*
Pack negative
(blk), 0V
Cell 5
Cell 6
Cell 4
Cell 3
Cell 2
Cell 1
* Nominal voltage with
respect to pack negative
FMA Cellpro Connector/FMA Wiring Mode
61