beautypg.com

ProgressiveRC DLS-27-40 IOTA User Manual

27vdc series power converter/charger, Owner’s manual, Protection features

background image

27VDC SERIES

POWER CONVERTER/CHARGER

OWNER’S MANUAL

The DLS series power converter/battery charger from
IOTA Engineering converts nominal A.C. voltage to volts
D.C. As a power supply, its tightly controlled regulation al-
lows the user to operate any appropriate nominal D.C. load
up to the converter’s rated output current. As a battery char-
ger, the converter will maintain the battery, delivering its
full-rated current when the battery capacity falls sufficiently
low. The voltage is set to deliver its maximum current for
the necessary period of time that minimizes undue stress
to the battery caused by heating of its cells. This helps to
ensure the longest possible life of the battery. Over time,
as the battery nears its full capacity, the converter will float-
charge the battery to prevent self-discharge of its cells.

PROTECTION FEATURES

The DLS series power converter/battery charger is de-
signed with high quality components to help ensure years
of continuous use. The DLS series is protected by multiple
protection features for a long, trouble-free life.

1) Reverse Battery Polarity Protection. 2) Brown-Out Input
Protection.
3) Over-Current Protection - cycle by cycle peak
limiting as well as rated current limiting to maximize the life
of the converter. 4) Over-Temperature Protection. In addi-
tion, it is designed with a unique “proportional” fan control
circuit. Fan speed is directly proportional to the converter’s
internal ambient temperature. This enables the fan to turn
on and off very slowly, minimizing unwanted fan-starting
noise.

The DLS series power converter/battery charger is war-
ranted from defects in materials or workmanship for two
years from date of retail purchase, and limits the remedies
to repair or replacement. This warranty is valid only in
the continental United States and Canada. For com-
plete warranty details, contact Customer Service or visit
www.iotaengineering.com

Distributed By:

WARRANTY

DC Output Voltage (No Load) approx.

Output Voltage Tolerance (No Load)

Output Amperage. Max Continuous

Output Voltage (Full Load) approx.

Maximum Power Output, Coninuous

Ripple and Noise

Input Voltage Range

Input Voltage Frequency

Maximum AC Current

Typical Efficiency

Max Inrush Current, Single Cycle

Short Circuit Protection

Overload Protection

Line Regulation

Load Regulation

Fan Control*

Thermal Protection

Working Temperature Range

Storage Temperature

Withstand Voltage

Dimensions**

Weight

27.2V (DC)

+ or - .5%

15 Amps

>27.0V (DC)

400 Watts

<50mV rms

108-132 AC

47-63

7.0 Amps

>80%

30 Amps

YES

>100%

100mV rms

<1%

PROPORTIONAL

YES

0 - 40C

-20 to 80C

1240V @ leads

9.7" x 6.7" x 3.4"

5.0 lbs

27.2V (DC)

+ or - .5%

25 Amps

>27.0V (DC)

675 Watts

<50mV rms

108-132 AC

47-63

11.6 Amps

>80%

40 Amps

YES

>100%

100mV rms

<1%

PROPORTIONAL

YES

0 - 40C

-20 to 80C

1240V @ leads

9.7" x 6.7" x 3.4"

5.0 lbs

27.2V (DC)

+ or - .5%

40 Amps

>27.0V (DC)

1100 Watts

<50mV rms

108-132 AC

47-63

20 Amps

>80%

50 Amps

YES

>100%

100mV rms

<1%

PROPORTIONAL

YES

0 - 40C

-20 to 80C

1240V @ leads

13" x 6.5" x 3.4"

7.8 lbs

DLS-27-15

DLS-27-25

DLS-27-40

P.O. BOX 11846 TUCSON, AZ 85734

(520) 294-3292 FAX (520) 741-2837

w w w . i o t a e n g i n e e r i n g . c o m

This manual is related to the following products: