beautypg.com

ProgressiveRC 4010Duo iCharger User Manual

Page 42

background image

iCharger Synchronous Balance Charger/Discharger

4010DUO

- 42 -

28XX

"Number of cells setting appears high"

Number of cells setting appears high

29XX

"Balance not needed, Remove connection from balance

port"

Balance port error, Ni-, Pb does not

need balance port, but voltage of

balance port is detected

30XX

"Balance required!"

Balance port is unplugged

31XX

"Auto detect the number of cells failed, please connect

balance or set cells"

Check connection or balance port

32XX

"AD watchdog error"

AD watchdog error

33XX

"Synchronous mode: Channel outputs imbalance"

Channel outputs are imbalance in

Synchronous mode

34XX

"This channel is needed to access the resistor or bulb

load"

This regenerative channel is needed

to access the resistor or bulb load

35XX

"The other channel is occupied"

The other channel is occupied