Press STATUS-x button for 2 seconds when running program to pop up MODIFY interface, to modify the current and

discharge voltage parameters online, as below:

Press STOP/START-x button when running program to stop running, and press STOP/START-x button again to return to

the initial interface.

Error Messages

During the running program, if the system detects an error, it will stop the program on the channel immediately and pop

up the red dialog box and the buzzer alarms, as below:

Program Edit

After adding new programs or editing saved programs, the system will enter MEMORY SETUP interface. Users can set

or modify the program on this interface.

Note: 1. When editing the program name, the character can be selected by turning the Knob, and

clicking the Knob to confirm the selected character. Clicking TAB/SYS button will delete the
character. Double-click Knob after editing program name. If the program name is empty, the
system will name it automatically.

2. If the Editing program is the built-in program, the program name and the types of battery

parameters cannot be changed.

After setting the basic parameters of a battery, click "

"

to enter MEMORY OPTION interface, after setting click

” to return to MEMORY SETUP, and click “

” to save.

1

2

1: Error number

2: Error message

See all details on Page41

Error Messages

.

1: Program name 2: Battery type

3: Number of cells 4: Battery capacity

5: Available program

Channel Mode:

Asynchronous (default);

Synchronous

Run Counter:

0-999; default: 0

Log Interval:

0.5-60Sec; default: 1Sec

5

2

3

4