Lipo/liio/life battery discharge safety setup, Nimh/nicd battery charge/discharge setup – ProgressiveRC 4010Duo iCharger User Manual
Page 21
iCharger Synchronous Balance Charger/Discharger
4010DUO
- 21 -
LiPo/LiIo/LiFe Battery Discharge Safety Setup
Click "
" to enter DISCHARGE SAFETY SETUP, after setting click"
" to return to the previous interface.
LiPo/LiIo/LiFe Battery Cycle Setup
Select Program→Cycle to enter Cycle setup interface, after setting click"
" to return to the previous interface.
LiPo/LiIo/LiFe Battery Only Balance Feature
Select Program→Balance Only to enter Balance Only setup interface, after setting click"
" to return to the previous
interface.
Note: Balance Only is the program only to equalize the individual cells through balance port to reduce
the voltage difference.
NiMH/NiCd Battery Charge/Discharge Setup
After adding a program, it will switch to NiMH/NiCd battery in Type option on the MEMORY SETUP interface. Set the
capacity, the number of cells for NiMH/NiCd battery cannot be set, and the charger sets Auto by default, after editing all
parameters for the program, click"
" to save and return to the previous interface.
As shown in above picture, the program of NiMH, NiCd has the following modes: Charge, Discharge and Cycle.
Cycle Mode:
CHG→DCHG(default),DCHG→CHG
,
CHG→DCHG CHG, DCHG→CHG DCHG,
CHG→DCHG STO, DCHG→CHG STO
Cycle Count:
1-99; default: 3
Delay Time:
0Min-9999Min; default: 3Min
Cut-Temp:
20
℃
-80
℃
; default: 45
℃
Max Capacity:
50%-200%; default: 90%
Safety Timer:
1Min-9999Min; default: off