Lipo/liio/life battery storage setup – ProgressiveRC 4010Duo iCharger User Manual
Page 19
iCharger Synchronous Balance Charger/Discharger
4010DUO
- 19 -
LiPo/LiIo/LiFe Battery Charge Advanced Setup
Click "
" to enter LiPo/LiIo/LiFe ADVANCED SETUP, after setting, click"
"to return to the previous
interface.
Note: 1. When charging the over-discharged battery, the charger will detect if the cell voltage is larger
than the restore voltage, if larger, it will pre-charge the battery with restore current, if within
the setting restore time, the cell voltage rises to the normal value then it will turn to the
charging program; otherwise it will stop running.
2. After charging, the battery may not be completely charged; tick Keep charging after the done
to charge the battery with smaller current when charging ends.
LiPo/LiIo/LiFe Battery Charge Safety Setup
Click "
" to enter CHARGE SAFETY SETUP, after setting click"
" to return to the previous interface.
Note: Cut-Temp. is the maximum safety temperature of the battery. If the temperature sensor detects
the set value, the program will stop running in order to protect the battery from being damaged
by high temperature.
LiPo/LiIo/LiFe Battery Storage Setup
This mode is for storing LiPo/LiIo/LiFe battery that will not to be used for an extended period. The charger determines
whether to charge or discharge the battery based on the configured target voltage. If the battery voltage exceeds the
target storage voltage it will start to discharge, while lower than the target storage voltage it will start to charge.
Select Program→Storage to enter Storage setup interface.
Note: 1. Accelerated storage: accelerated storage via internal resistance correction. Tick Accelerated
storage to activate accelerated storage.
2. Storage Compensation is the compensation for the battery voltage fallback: for storage charge,
the actual storage voltage=Storage Cell Voltage + Storage Compensation; for storage discharge,
the actual storage voltage=Storage Cell Voltage - Storage Compensation.
Restore Lowest Voltage:
0.5V/Cell-2.5V/Cell; Default: 1V/Cell
Restore Charge Time:
1Min-5Min; default: 3Min
Restore Charge Current:
0.02A-0.5A; default: 0.1A
Cut-Temp:
20
℃
-80
℃
; default: 45
℃
Max Capacity:
50%-200%; default: 120%
Safety Timer:
0Min-9999Min; default: off
Storage Cell Voltage:
3.7V/Cell-3.9V/Cell;
Default: 3.85V/Cell
Storage Compensation:
0V/Cell-0.2V/Cell;
Default: 0.01V/Cell