beautypg.com

Nizn battery charge/discharge setup – ProgressiveRC 4010Duo iCharger User Manual

Page 24

background image

iCharger Synchronous Balance Charger/Discharger

4010DUO

- 24 -

Pb Battery Charge Advanced Setup

Click "

" to enter PB ADVANCED SETUP interface

Note: When charging the over-discharged battery, the charger will detect if the cell voltage is larger

than the restore voltage, if larger, it will pre-charge the battery with restore current, if within the
setting restore time, the cell voltage rises to the normal value then it will turn to the charging
program; otherwise it will stop running.

Pb Battery Charge Safety Setup

Click "

" to enter CHARGE SAFETY SETUP interface, see details about setting on Page19 LiPo/LiIo/LiFe Battery

Charge Safety Setup.

Pb Battery Discharge Setup

Select Program→Discharge to enter Discharge setup interface, see details about setting on Page20 LiPo/LiIo/LiFe

Battery Discharge Setup.

Pb Battery Cycle Setup

Select Program→Cycle to enter Cycle setup interface, see details about setting on Page21 LiPo/LiIo/LiFe Battery Cycle

Setup.

NiZn Battery Charge/Discharge Setup

After adding a program, it will switch to NiZn battery in Type option on the MEMORY SETUP interface. Set the capacity,

the number of cells for NiZn battery cannot be set, and the charger sets Auto by default, after editing all parameters for

the program, click"

" to save and return to the previous interface.

As shown in above picture, the program of NiZn has the following modes: Charge, Discharge and Cycle.

Cells: 1-8S; default: Auto