ProgressiveRC 4010Duo iCharger User Manual
Page 29

iCharger Synchronous Balance Charger/Discharger
4010DUO
- 29 -
Power Supply Setup
Select SYSTEM MENU→Charger Setup→Power Supply to enter the setup interface.
After selecting input source, click the "
" followed by the option, enters the relevant power supply setting to
set the parameters, after setting click “
”to save and return to the previous interface.
Save & Load Configuration Setup
Select Save & Load Config on SYSTEM MENU and enter the setup interface.
Note: 1. Users can save configuration to SD card and re-load via the SD card if needed.
2. After loading the configuration files, in addition to Calibration Select, it will cover all settings
within the charger.
Low Voltage Limit:
9V-48V; default: 10V
Current Limit:
1A-65A; default: 65A
Low Voltage Limit:
9V-48V; default: 10V
Current Limit:
1A-65A; default: 65A
Regen.Voltage Limit:
9V-48V; default: 14.5V
Regen. Current Limit:
1A-65A; default: 10A
Regen. Capacity Limit:
Ignore (default)
100mAh-999900mAh
After ticking Regenerative enable, if run the
regenerative discharge to input, the electrical
discharged will be re-charged as the battery of
input power.
1
2
1: DC Power
2: Battery Power
1
2
3
1: Save Configuration to SD card
2: Load Configuration from SD card
3: Load Defaults Configuration