Power Supply Setup

Select SYSTEM MENU→Charger Setup→Power Supply to enter the setup interface.

After selecting input source, click the "

" followed by the option, enters the relevant power supply setting to

set the parameters, after setting click “

”to save and return to the previous interface.

Save & Load Configuration Setup

Select Save & Load Config on SYSTEM MENU and enter the setup interface.

Note: 1. Users can save configuration to SD card and re-load via the SD card if needed.

2. After loading the configuration files, in addition to Calibration Select, it will cover all settings

within the charger.

Low Voltage Limit:

9V-48V; default: 10V

Current Limit:

1A-65A; default: 65A

Low Voltage Limit:

9V-48V; default: 10V

Current Limit:

1A-65A; default: 65A

Regen.Voltage Limit:

9V-48V; default: 14.5V

Regen. Current Limit:

1A-65A; default: 10A

Regen. Capacity Limit:

Ignore (default)

100mAh-999900mAh

After ticking Regenerative enable, if run the

regenerative discharge to input, the electrical

discharged will be re-charged as the battery of

input power.

1

2

1: DC Power

2: Battery Power

1
2
3

1: Save Configuration to SD card

2: Load Configuration from SD card

3: Load Defaults Configuration