Nizn battery charge setup, Nizn battery discharge setup, To channel setup – ProgressiveRC 4010Duo iCharger User Manual
Page 25
iCharger Synchronous Balance Charger/Discharger
4010DUO
- 25 -
NiZn Battery Charge Setup
Select Program→Charge to enter Charge setup interface.
Note: When the battery cell charging voltage setting exceeds the recommended value (1.9V), there will be a
warning display and alarm voice. As long as the user changes the value, the battery type and cell voltage
values on the main interface of charger will display alternately.
NiZn Battery Not Balance Charger Setup
Switch to Not Balance mode on Chg Mode interface, see details about setting on Page17 LiPo/LiIo/LiFe Battery Not
Balance Charge Setup.
NiZn Battery Balance Charge Setup
Switch to Slow Balance
,
Normal Balance
,
Fast Balance
,
User Balance on Chg Mode interface, see details about setting
on Page17 LiPo/LiIo/LiFe Battery Balance Charge Setup.
NiZn Battery Charge Advanced Setup
Click "
" to enter NIZN ADVANCED SETUP interface, see details about setting on Page19 LiPo/LiIo/LiFe
Battery Charge Advanced Setup.
NiZn Battery Charge Safety Setup
Click "
" to enter CHARGE SAFETY SETUP interface, see details about setting on Page19 LiPo/LiIo/LiFe Battery
NiZn Battery Discharge Setup
Select Program→Discharge to enter Discharge setup interface
Note: 1.The charger first discharges with constant current (CC) according to the user setting then turns
to constant voltage (CV) when it reaches the discharge voltage. In the CV phase the current
gradually falls, and the charger will terminate discharging when the current falls below the
percentage of the configured discharge current.
2. Regenerative mode has three available settings: OFF, To input, To channel, see more details on
To Channel Setup
Switch to To channel mode on Regenerative Mode interface, click“
”to enter To channel setup interface, see
details about setting on Page20 To Channel Setup.
Chg Current:
0.05A-30A; default: 2A
Chg Mode:
Slow Balance, Fast Balance,
Normal Balance, User Balance,
Not Balance( default)
Chg End Current
1%-50%; default:10%
Chg Cell Volt
1.2V/Cell-2V/Cell; default: 1.9V/Cell
Discharge Current:
0.05A-30A; default: 2A
Discharge Voltage:
0.9V/Cell-1.6V/Cell;
default: 1.1V/Cell
End Current:
1%-100%; default: 50%
Regenerative Mode:
OFF (default),To input, To channel