18
R E L I A N C E S T O R M M A X I N S T A L L A T I O N M A N U A L
Optional Seal
Optional seal
Head seal is similar
2.4 a. Position backer rod around the perimeter of the frame.
b. Clean gap area on frames with isopropyl alcohol (50%) and wipe clean.
c. Apply Dow Corning 795 silicone sealant to the perimeter of the frame.
(Interior seal is optional)
Backer Rod and
Dow Corning 795
Silicone Sealant
Backer Rod and
Dow Corning 795
Silicone Sealant
PERIMETER SEALANT APPLICATION
FIGURE 2.4a
Jamb Condition
FIGURE 2.4b
Sill Condition