Steel-channel-reinf – Oldcastle BuildingEnvelope Reliance StormMax User Manual
Page 11

8
R E L I A N C E S T O R M M A X I N S T A L L A T I O N M A N U A L
1.5 a. Insert RS-25 reinforcement steel into HW-500 jamb or mullion
(Steel Height = mullion Height Minus 6")
b.Prior to HW-183-01 shear block attachment insert HW-200-01 anchor sleeves at
HW-500 vertical mullion ends and match drill .191 dia. hole.
c. Attach HW-183-01 shear block to HW-500 vertical mullion with FS-9 fastener
d. Attach RS-25 reinforcement steel to HW-500 Jamb or mullion with (2) FS-322
fasteners to be located within the intermediate horizontal shear block as show in FIGURE 1.5a
e. Install FG-5185 interior spacer gasket cut to 2" from ends and 2" gaps at
horizontal to allow for WW-352 zone plugs.
f. Install and seal HW-325 end caps to top and bottom of HW-500 vertical mullion
screw boss with (2) FS-320 #10 x 1/2" drive screw.
HW-200-01 Anchor Sleeve
(for design pressures above 70 psf)
HW-500 Intermediate vertical mullion
HW-183-01 shear block
Drill #25 - .1495" pilot hole
install (2) FS-322 Fasteners
HW-338 for Jambs
and HW-325 for mullions
Seal and tool sealant on end caps
Steel Height = mullion Height Minus 6"
RS-25 Reinforcement Steel
(4) FS-9 Fasteners
FIGURE 1.5
FIGURE 1.5a
(2) FS-320 Drive Screw
ALTERNATIVE REINFORCEMENT STEEL CHANNEL