8serial port interfaces, 1 connectors, Jrex plus - dc user's guide – Kontron JRexplus-DC User Manual
Page 25
KTD-S0008-F
Page 20
Serial Port Interfaces
JRexplus-DC User's Guide
8
Serial Port Interfaces
Two fully functional serial ports (COMA and COMB) provide asynchronous serial communications. COMA and
COMB support RS-232 operation modes. They are 16550 high-speed UART compatible and support 16-byte
FIFO buffers for transfer rates from 50 Baud to 115.2 kBaud. A programmable baud rate generator allows
transfer rates up to 1 MBaud.
One serial port is available as RS-232 on the JRex front panel and can be used as well as RS-422 or RS-485
interface, the second serial port COMB is available through a 10 pin header.
8.1
Connectors
COMA is available through the standard DSUB9 connector J28 (9 pins).
Header
Pin
Signal Name
Function
DSUB25
1
/DCD
Data carrier detect
8
2
RXD
Receive data
3
3
TXD
Transmit data
2
4
/DTR
Data terminal ready
20
5
GND
Ground
7
6
/DSR
Data set ready
6
7
/RTS
Request to send
4
8
/CTS
Clear to send
5
1
5
9
6
9
/RI
Ring indicator
22
The same connector J28 can be used as a RS-422 or RS-485 interface. The configuration is changeable in
the BIOS Setup.
Header
Pin
RS-422
RS-485
Function
1
TX-
TX- / RX-
Transmit data - / Receive data -
2
N.C.
N.C.
Not connected
3
TX+
TX+ / RX+
Transmit data + / Receive data +
4
N.C.
N.C.
Not connected
5
GND
GND
Ground
6
RX+
N.C.
Receive data + / Not connected
7
N.C.
N.C.
Not connected
8
RX-
N.C.
Receive data - / Not connected
1
5
9
6
9
N.C.
N.C.
Not connected
Attention: A RS-422/RS-485 terminating resistor is not equipped on the JRexplus-DC.