Kontron FRU Over Current
Kontron FRU Power Denied
Kontron Reset
Table 4-11: Kontron FRU over current sensor
Event/Reading
type code
Sensor type
Sensor specific
offset
Event trigger
0x6F
0xCB
OEM Kontron
FRU Over Current
0x00
0x01
State Asserted /
State Deasserted
Event Data 2:
0x00: Over Current on Management power.
0x01: Over Current on Payload power.
Event Data 3:FRU ID
Table 4-12: Kontron FRU Power Denied sensor
Event/Reading
type code
Sensor type
Sensor specific
offset
Event trigger
0x03
0xCD
OEM Kontron
FRU Power
Denied
0x00
0x01
State Asserted /
State Deasserted
Event Data 2: undef ined
Event Data 3: FRU ID
Table 4-13: Kontron reset sensor
Event/Reading
type code
Sensor type
Sensor specific
offset
Event trigger
0x6F
0xCA
OEM Kontron
RESET
0x00
0x01
State Asserted /
State Deasserted
Event Data 2: Reset Type
0x00: Warm reset
0x01: Cold reset
0x02: Forced Cold [ Warm reset reverted to Cold ]
0x03: Soft reset [ Software jump ]
Event Data 3: Reset Source
0x00: IPMI Watchdog [cold, warm or forced cold]
( IPMI Watchdog2 sensors gives additionnal details
)
0x01: IPMI commands [cold, warm or forced cold]
( Chassis control, FRU control )
0x02: Processor internal checkstop
0x03: Processor internal reset request
0x04: Reset button [warm or forced cold]
0x05: Power up [ cold ]
0x06: Legacy Initial Watchdog / Warm Reset Loop
Detection * [cold reset]
0x07: Legacy Programmable Watchdog [cold, warm
or forced cold]
0x08: Software Initiated [soft, cold, warm of
forced cold]
0x09: Setup Reset [Software Initiated Cold]