Figure 5-3: configuration b - airflow measurement – Kontron AT8404 User Manual
Page 123
Thermal Considerations
110
AT8404 User Guide
www.kontron.com
In configuration B, all four AMC slots are populated with air blocker modules. The air blockers simulate the
maximum component envelope which is allowed on an AMC. This corresponds to the highest possible air
impedance.
Figure 5-3: Configuration B - Airflow Measurement
The airflow through the AT8404 component area behind the AMC connectors is well balanced due to the
impedance given by the power mezzanine. This prevents excessive air bypass when the AMC area is loaded
with high impedance AMCs.
Partially stuffed AT8404 or AT8404 with low profile AMCs should use blank fillers or other means providing
sufficient flow resistance to get close to the CP-TA impedance reference curve.
0
10
20
30
40
50
60
70
80
90
100
0
0,2
0,4
0,6
0,8
1
1,2
1,4
Airflow (CMM)
Pr
es
su
re
(
P
a
)
Front Board Reference
0,00
0,02
0,04
0,06
0,08
0,10
0,12
0,14
1
2
3
4
5
6
7
8
Test Section
CM
M
- CP3003-SA uEFI BIOS (72 pages)
- CP3003-SA (36 pages)
- CP3002 (38 pages)
- CP3002-RC uEFI (64 pages)
- CP-RIO3-05 (42 pages)
- CP3002-RC (30 pages)
- CP342 (52 pages)
- CP930 (46 pages)
- CP932 (52 pages)
- CP346 (72 pages)
- CP384 (66 pages)
- CP383 (74 pages)
- CP382 (58 pages)
- CP381 (60 pages)
- CP372 (64 pages)
- CP371 (60 pages)
- CP-RIO3-04S (38 pages)
- CP390 (36 pages)
- CPS3410 (9 pages)
- CPS3402 (9 pages)
- CPS3105 (9 pages)
- CPS3101 (9 pages)
- CPS3003-SA (19 pages)
- PB-SIO4 (34 pages)
- PB-SIO4A (34 pages)
- PB-DOUT8 (34 pages)
- VMOD-2 (82 pages)
- VSBC-32 (110 pages)
- VM42 (62 pages)
- Bootstrap Loader (24 pages)
- VMP1 with Netbootloader (120 pages)
- VMP1 (106 pages)
- NetBootLoader (86 pages)
- VMP2 (142 pages)
- VMP3 (154 pages)
- CP-RIO6-923 (32 pages)
- CP-RIO6-923-F (32 pages)
- CP-RIO6-001 (28 pages)
- CP-RIO6-001-HD-VGA (46 pages)
- CP-RIO6-M (20 pages)
- CP-RIO6-B (28 pages)
- CP6925 (42 pages)
- CP6002 uEFI BIOS (76 pages)
- CP6002 IPMI (40 pages)
- CP6002 (42 pages)