beautypg.com

Kontron AT8404 User Manual

Page 72

background image

Software Description

59

AT8404 User Guide

www.kontron.com

39

FRU4 Pwr
Denied

0xCD
(FRU Power
denied)

0x03
(Digital Dis-
crete)

Generates an event
when power for this
FRU was denied.

offset 0,1 are used,
offset 0: event trigger, Nor-
mal Condition (Power Deny
deasserted)
offset 1: event trigger, Shelf
Manager deny Power to this
FRU
for details see 4.3.1.1 OEM
sensor description

40

FRU5 Pwr
Denied

0xCD
(FRU Power
denied)

0x03
(Digital Dis-
crete)

Generates an event
when power for this
FRU was denied.

offset 0,1 are used,
offset 0: event trigger, Nor-
mal Condition (Power Deny
deasserted)
offset 1: event trigger, Shelf
Manager deny Power to this
FRU
for details see 4.3.1.1 OEM
sensor description

41

Temp PCB
Outlet

0x01
(Temperature)

0x01
(Threshold)

PCB Outlet temperature

For sensor thresholds, see
Table 4-18 on page 67

42

Temp BCM
Outlet

0x01
(Temperature)

0x01
(Threshold)

BCM Outlet tempera-
ture

For sensor thresholds, see
Table 4-18 on page 67

43

Temp AMC
Outlet

0x01
(Temperature)

0x01
(Threshold)

AMC Outlet tempera-
ture

For sensor thresholds, see
Table 4-18 on page 67

44

Temp PPC
Inlet

0x01
(Temperature)

0x01
(Threshold)

PowerPC Inlet tempera-
ture

For sensor thresholds, see
Table 4-18 on page 67

45

Temp AMC
Inlet

0x01
(Temperature)

0x01
(Threshold)

AMC Inlet temperature

For sensor thresholds, see
Table 4-18 on page 67

46

Temp PPC
Outlet

0x01
(Temperature)

0x01
(Threshold)

PowerPC Outlet temper-
ature

For sensor thresholds, see
Table 4-18 on page 67

47

Icc 12v FRU0

0x03
(Current)

0x01
(Threshold)

Current on 12v board
power supply

For sensor thresholds, see
Table 4-16 on page 66

48

Vcc 12v
FRU0

0x02
(Voltage)

0x01
(Threshold)

Voltage on 12v board
power supply

For sensor thresholds, see
Table 4-17 on page 67

49

Icc 3.3vSus
FRU0

0x03
(Current)

0x01
(Threshold)

Current on 3.3v sus-
pend (management)
power supply

For sensor thresholds, see
Table 4-16 on page 66

50

Vcc 3.3vSus
FRU0

0x02
(Voltage)

0x01
(Threshold)

Voltage on 3.3v sus-
pend (management)
power supply

For sensor thresholds, see
Table 4-17 on page 67

51

Vcc 1.2vSUS
FRU0

0x02
(Voltage)

0x01
(Threshold)

Voltage on 1.2v sus-
pend (management)
power supply

For sensor thresholds, see
Table 4-17 on page 67

52

Vcc 3.3v
FRU0

0x02
(Voltage)

0x01
(Threshold)

Voltage on 3.3v board
power supply

For sensor thresholds, see
Table 4-17 on page 67

Table 4-4:

AT8404 sensors (Continued)

SDR

ID

Name

Sensor Type

Code

Reading Type

Code

Description

Event Offset