Kontron AT8404 User Manual
Page 21
Introduction
8
AT8404 User Guide
www.kontron.com
Gen
er
al
Humidity
Designed to meet or exceed the following:
•
Bellcore GR-63, Section 4.1
•
Operating: 15%-90% (non-condensing) at 55°C (131°F)
•
Non-Operating: 5%-95% (non-condensing) at 40°C (104°F)
Altitude
Designed to meet or exceed the following:
•
Operating: 4000 m (13123 ft)
•
Non-operating: 15000 m (49212 ft)
Vibration
Designed to meet or exceed the following:
•
Bellcore GR-63, Section 4.4
•
ETSI EN 300 019-2-3
•
Operating: Sinusoidal 1.0G (5-100Hz), 0.2G (100-200Hz), each axis
•
Packaged: Random 0.89Grms (5-200Hz), each axis
Shock
Designed to meet or exceed the following:
•
DIN/IEC 60068-2-27
•
Bellcore GR-63, Section 4.3
•
ETSI EN 300 019-2-3
•
Operating: 3G, half-sine 11ms, each axis
•
Packaged: 18G, half-sine 6ms, each axis
Safety
Designed to meet or exceed the following:
•
CB report to IEC 60950-1, complies with EN/CSA/ UL 60950-1
EMC
Designed to meet or exceed the following:
•
FCC 47 CFR Part 15, Subpart B
•
EN55022, EN55024
•
EN 300 386
Reliability
•
MTBF: > 384,000 hours @ 40°C/104°F (Telcordia SR-332, Issue 1)
HW Mo
nit
or
ing
LEDs
ATCA LEDs:
•
4 LEDs ("Ready for Hot Swap", "Out of Service", "Healthy", "Activity")
Board Management
•
based on IPMI 1.5
•
FRU Management
•
Sensors (Voltage, Current, Temperature, Fuse)
•
Status and Alerting
•
Hot Swap Management for Base Board and AMC
•
Electronic Keying of Base and Fabric Interfaces and AMC ports
•
Local SEL
Table 1-2:
AT8404 Main Specifications
AT8404
SPECIFICATIONS