9 power supply, Table 3-15: j32 assignment – Kontron AT8404 User Manual
Page 45
Hardware Description
32
AT8404 User Guide
www.kontron.com
Signals with TX in their name are driven by the front board, those with RX are driven by the RTM.
3.1.9 Power Supply
The power supply fulfils the PICMG3.0 requirements and has the following characteristics:
• Full operation at -38VDC to -72VDC
• No damage inflicted to board at 0VDC to -75VDC
• Typical payload power consumption (no RTM, no AMCs): 40W
• Management power consumption (suspend power): <10W
• Additional AMC payload power consumption: 140W
Table 3-15: J32 Assignment
J32
ROW A
AB
ROW B
ROW C
CD
ROW D
1
N.C.
GND
N.C.
N.C.
GND
N.C.
2
AMC_B2_P14_TX+
GND
AMC_B2_P14_TX-
AMC_B2_P14_RX+
GND
AMC_B2_P14_RX-
3
N.C.
GND
N.C.
N.C.
GND
N.C.
4
AMC_B3_P14_TX+
GND
AMC_B3_P14_TX-
AMC_B3_P14_RX+
GND
AMC_B3_P14_RX-
5
AMC_B3_P17_TX+
GND
AMC_B3_P17_TX-
AMC_B3_P17_RX+
GND
AMC_B3_P17_RX-
6
AMC_B3_P19_TX+
GND
AMC_B3_P19_TX-
AMC_B3_P19_RX+
GND
AMC_B3_P19_RX-
7
N.C.
GND
N.C.
N.C.
GND
N.C.
8
AMC_B4_P14_TX+
GND
AMC_B4_P14_TX-
AMC_B4_P14_RX+
GND
AMC_B4_P14_RX-
9
AMC_B4_P17_TX+
GND
AMC_B4_P17_TX-
AMC_B4_P17_RX+
GND
AMC_B4_P17_RX-
10
AMC_B4_P19_TX+
GND
AMC_B4_P19_TX-
AMC_B4_P19_RX+
GND
AMC_B4_P19_RX-
J32
ROW E
EF
ROW F
ROW G
GH
ROW H
1
AMC_B2_P13_TX+
GND
AMC_B2_P13_TX-
AMC_B2_P13_RX+
GND
AMC_B2_P13_RX-
2
N.C.
GND
N.C.
N.C.
GND
N.C.
3
AMC_B3_P13_TX+
GND
AMC_B3_P13_TX-
AMC_B3_P13_RX+
GND
AMC_B3_P13_RX-
4
N.C.
GND
N.C.
N.C.
GND
N.C.
5
AMC_B3_P18_TX+
GND
AMC_B3_P18_TX-
AMC_B3_P18_RX+
GND
AMC_B3_P18_RX-
6
AMC_B3_P20_TX+
GND
AMC_B3_P20_TX-
AMC_B3_P20_RX+
GND
AMC_B3_P20_RX-
7
AMC_B4_P13_TX+
GND
AMC_B4_P13_TX-
AMC_B4_P13_RX+
GND
AMC_B4_P13_RX-
8
N.C.
GND
N.C.
N.C.
GND
N.C.
9
AMC_B4_P18_TX+
GND
AMC_B4_P18_TX-
AMC_B4_P18_RX+
GND
AMC_B4_P18_RX-
10
AMC_B4_P20_TX+
GND
AMC_B4_P20_TX-
AMC_B4_P20_RX+
GND
AMC_B4_P20_RX-