beautypg.com

Elecraft XG3 RF User Manual

Page 23

background image

23

Program sweep memory 01, start at 7.020 MHz, end at 7.120 MHz, step at 100 Hz, 10 ms per step, no 
repeat 

Send:  

Q,01,00007020000,00007120000,00000000100,00010,00; 

 

 

 

 

XG3: nothing 

Program sweep memory 02, start: 145 MHz, end: 146 MHz, step: 20 KHz, 5 seconds per step, repeat 

Send:  

Q,02,00145000000,00146000000,00000020000,05000,01; 

 

 

 

 

XG3: nothing 

Send Q,01; 

XG3:  Q,01,00007020000,00007120000,00000000100,00010,00; 

S,[sweep#]

Run programmable sweep 1 or 2
When the sweep is running, sending any command except the (I)nfo command and ‘;’ will terminate
the sweep. This allows the Info command to be used to determine the current frequency during the
sweep. See Q command for programming the 2 sweep memories.
Send: S,01; 

XG3: nothing 

T[,control]

Turn on/off tech mode.
Enables/disables tech mode. Certain commands are disabled by default. Enabling tech mode allows
access to these commands. Tech mode is disabled by default and is not saved during a power down.
(see tech mode section at the end of this document)
Send: 

T,01; 

 

 

turns tech mode on 

XG3: nothing 

Send T; 

XG3: T,01; 

V

Display current version
Send:

V;

XG3:

V,1.00;

X

Power off
Turns the power off on the unit.
Once this command is executed, the power to the unit will be turned off.
Enter: X;