G[,led brightness level]

Set/display the current LED brightness level.

Send: G,02; 

XG3: nothing 

Send: G; 

XG3: G,02; 
Sets the LED brightness or views the current setting. Valid brightness settings are 0 (brightest), 1, 2, 3
(dimmest).

H

?
Display help screen.
Displays the list of currently supported commands. Note: additional commands may be added at a
future date.

I

Display current informational status.
Send:  

I; 

XG3:   

I,00146000000,02,11,00,01,00,00,00; 

Position Description

0

Echoed ‘I’ command

1

Current frequency in MHz, represented using 11 digits with leading zeros

2

Current Level: 00 = 0dBm, 01 = -33, 02 = -73, 03 = -107

3

Current band memory: 00 - 11

4

Output: 01 = on, 00 = off

5

PLL Lock: 01 = locked, 00 = unlocked

6-8 Future

use

L[,level#]

Set current output level or display current output level.
Valid levels are 0 ,1,2 or 3. 0 = 0 dBm, 1 = -33 dBm, 2 = -73 dBm, 3 = -107 dBm
Send: L,02;   

sets output level to ‐73dBm 

XG3: nothing 
Send L; 
XG3: L,02; 

M,location#[,frequency]

Program or view the specified memory location.
Valid memory locations are 0 - 11. Memory location# is a required argument. If no frequency
argument is given, the contents of that memory location will be displayed. Frequencies are entered