Delayed egress operations, Battery backup for alarm, Low battery indication – Detex V40 EE User Manual
Page 13

Turn Key CW To Disarm
Glowing Green LED
Red LED while alarming
EXITING UNDER ALARM
ARMING AND AUTHORIZED EXIT
Turn Key CCW To Arm
DISARMING
For BENCH TESTING:
push and hold deadlatch while
performing alarm test operations
Deadlatch
(LHR shown)
Red LED
Green LED
Cylinder
Mortise
PushPad
Siren
Home Key
Position
NORMAL OPERATION
NUISANCE DELAY
With door closed, insert key in the cylinder, turn CCW then back to the home key position and remove it.
The red LED blinks twice then the green LED glows continuously. Authorized personnel can exit the
door during this rearm cycle. After a 1, 5 or 15 second arming period, the alarm issues three quick
beeps and the green LED goes off, indicating that the unit is armed.
Insert key, turn CW to a stop. Green LED will blink twice to indicate the unit is disarmed.
To exit, push and maintain pressure on the pushpad. After a one-second delay, (nuisance delay), LED
flashes RED and alarm pulses on and off for 15 seconds. After 15 seconds, alarm issues short and
long pulses to indicate that you can exit by depressing the pushpad. Alarm sounds continuously and LED
is steady RED. Turn key CW to stop alarm.
When pushpad is depressed for less than 1
second, alarm will emit a single pulse but
will not start delay function.
DELAYED EGRESS OPERATIONS
Indicates the unit is in process of arming. The siren will chirp three times to indicate the unit
is armed and green LED will turn off
DOUBLE BLINK
DOUBLE CHIRP
OFF
Low Battery - every 45 seconds
LED COLOR
SLOW BLINKING
FAST BLINKING
ON
ON
OFF
RED
OFF
Pushpad is depressed, delay to open started
This indicates either armed or disarmed
Delay to open expired
Delay to open expired, door has been opened
ON
SLOW PULSE
FAST PULSE
OFF
OFF
OFF
ON
OFF
SIREN SOUNDS
THREE CHIRPS
GREEN
ON
FUNCTION
Factory installed jumper removed from 3 & 4 terminals
BLINK
BLINK
OFF
OFF
Armed - status ON
Disarmed - status ON
BATTERY BACKUP FOR ALARM
A 9-volt battery is included as a backup power source for the alarm siren if power is lost.
To disable low battery indication, slide the DisLoBat switch to 'ON'. See page 16 for location.
LOW BATTERY INDICATION
If battery voltage is low(7 volts or less), unit remains armed but LED flashes RED and unit beeps
twice every 45 seconds. Replace battery as soon as possible.