beautypg.com

Hierarchy, Figure 2: iipc hierarchy, Interlaken_1 – Achronix Speedster22i Interlaken User Manual

Page 9

background image

Hierarchy

The interfaced IIPC and SerDes IP is configured using the Achronix Cad Environment (ACE)

Interlaken GUI.
The upper-levels of hierarchy are shown in Figure 2. Note that the text in Figure 2 represents the

name of the module at that level of hierarchy.

Figure 2: IIPC Hierarchy

The top-level wrapper module, Interlaken_1, contains the instantiated hard IIPC block and an

instantiated hard SerDes block for each lane. The module Interlaken_1_serdes wraps the Achronix

SerDes block and sets configuration parameters needed for proper Interlaken operation.

User’s Tasks:

The ACE Interlaken GUI should be used to configure the Interlaken core. This will

automatically instantiate the SerDes lanes and produces a single top level wrapper that

can be included in your design.

Connect the Local Bus (LBUS) user-side interface at the fabric to the wrapper

Provide the appropriate clock signals to the wrapper


Interlaken_1_serdes

ACX_INTERLAKEN_TOP

(IIPC core)

Interlaken_1

UG032, May 15, 2014

9