Achronix Speedster22i Interlaken User Manual
Page 44

0x0C80
to
0x0CAE
statistics
counters
RX Descrambler Error Statistics Registers – RO
0x0C80 Bit 15:0 – returns the value contained in bits 15-0 (LSB) of RX
Descrambler Error Statistics register for lane 0
0x0C82 Bit 15:0 – returns the value contained in bits 31-16 (MSB) of
RX Descrambler Error Statistics register for lane 0
0x0C84 Bit 15:0 – returns the value contained in bits 15-0 (LSB) of RX
Descrambler Error Statistics register for lane 1
0x0C86 Bit 15:0 – returns the value contained in bits 31-16 (MSB) of
RX Descrambler Error Statistics register for lane 1
Continues for all 12 lanes (0-11) up to address 0x0CAE
0x1000
to
0x17FE
statistics
counters
RX Channel Good/Bad Packet Count Registers – RO
0x1000 Bit 15:0 – returns the value contained in bits 15-0 (LSB) of RX
Channel 0 Good Packet Count
0x1002 Bit 15:0 – returns the value contained in bits 31-16 (MSB) of
RX Channel 0 Good Packet Count
0x1004 Bit 15:0 – returns the value contained in bits 15-0 (LSB) of RX
Channel 0 Bad Packet Count
0x1006 Bit 15:0 – returns the value contained in bits 31-16 (MSB) of
RX Channel 0 Bad Packet Count
0x1008 Bit 15:0 – returns the value contained in bits 15-0 (LSB) of RX
Channel 1 Good Packet Count
0x100A Bit 15:0 – returns the value contained in bits 31-16 (MSB) of
RX Channel 1 Good Packet Count
0x100C Bit 15:0 – returns the value contained in bits 15-0 (LSB) of RX
Channel 1 Bad Packet Count
0x100E Bit 15:0 – returns the value contained in bits 31-16 (MSB) of
RX Channel 1 Bad Packet Count
Continues for all 256 Channels (0-255) up to address 0x17FE
The Default value of all registers is ‘h00.
UG032, May 15, 2014
44