Before you Begin
• At any point in this procedure, return to a prior state by pressing
• A maximum of eight virtual disks can be created with the PERC BIOS
Configuration
Utility.
NOTE:
Mixing of RAID levels is not allowed on same physical disk(s).
NOTE:
The Create Virtual Disk operation is not selectable when there is no
available capacity on the physical disks.
1 Power-up the system to start booting.
2 When prompted, press the
Configuration Utility.
3 At the Main Menu field, use the arrow keys to select Create Virtual
Disk. Press
4 At the Physical Disks field, select the physical disk(s) on which to create
a virtual disk:
a
For each physical disk, press the
disk. (The physical disks can be inserted in any order.)
b
After selecting the physical disk(s) to be included in the virtual disk,
press
5 At the User Input field, use the arrow keys to select a virtual disk type
(RAID level). Press
created with the selected physical disk(s) that are indicated; they are
highlighted in white text).
6 If hot spares are applicable:
a
At the User Input field, use the arrow keys to select a dedicated hot
spare. Press
NOTE:
A hot spare can be assigned after a virtual disk is created, by selecting
the Manage Hot Spare(s) option.
b
At the Physical Disks field, select the physical disk to use as a hot
spare (if applicable). Press
c
Press
the change.