Dell DX6000 User Manual
Page 50

50
About Your System
The following
DIMMs should
match
in
geometry:
x,x,...
Invalid memory
configuration. The specified
memory modules do not
match in size, number of
ranks, or number of data
lanes.
Ensure that the memory
modules are installed in a
valid configuration.
See "General Memory
The following
DIMMs should
match
in rank
count:
x,x,...
The following
DIMMs should
match in size:
x,x,...
The following
DIMMs should
match
in size
and geometry:
x,x,...
The following
DIMMs should
match
in size
and rank count:
x,x,...
Thermal sensor
not detected on
x.
A memory module without a
thermal sensor is installed in
the specified memory slot
Replace the memory module.
Time-of-day
clock stopped.
Faulty battery or faulty chip. See "Troubleshooting the
Time-of-day not
set - please run
SETUP program.
Incorrect Time or Date
settings; faulty system
battery.
Check the Time and Date
settings. See "Using the
page 57. If the problem
persists, replace the system
battery. See "System Battery"
Table 1-2. System Messages
(continued)
Message
Causes
Corrective Actions