29
E1629
Power
required >
PSU wattage.
Check PSU and
config.
The system configuration
requires more power than
the power supplies can
provide, even with
throttling.
Turn off power to the
system, reduce the
hardware configuration or
install higher-wattage
power supplies, and then
restart the system.
E1710
I/O channel
check error.
Review &
clear SEL.
The system BIOS has
reported an I/O channel
check.
Check the SEL for more
information and then
clear the SEL. Remove
AC power to the system
for 10 seconds and restart
the system.
If the problem persists,
E1711
PCI parity
error on Bus
## Device ##
Function ##
The system BIOS has
reported a PCI parity error
on a component that
resides in PCI
configuration space at bus
##, device ##, function
##.
Remove and reseat the
PCIe expansion cards. If
the problem persists, see
PCI parity
error on Slot
#. Review &
clear SEL.
The system BIOS has
reported a PCI parity error
on a component that
resides in the specified slot.
Remove and reseat the
PCIe expansion cards. If
the problem persists, see
Table 1-1. LCD Status Messages
(continued)
Code
Text
Cause
Corrective Actions