About Your System

Gate A20 failure

Faulty keyboard controller; faulty
system board.

See "Getting Help" on page 129.

General failure

The operating system is unable to
carry out the command.

This message is usually followed by
specific information. Note the
information and take the appropriate
action to resolve the problem.

Invalid NVRAM

configuration, Resource

Re-allocated

System detected and corrected a
resource conflict.

No action is required.

Keyboard Controller

failure

Faulty keyboard controller; faulty
system board

See "Getting Help" on page 129.

Manufacturing mode

detected

System is in manufacturing mode.

Reboot to take the system out of
manufacturing mode.

Memory address line

failure at

address

, read

value

expecting

value

Faulty or improperly installed memory
modules.

See "Troubleshooting System Memory"
on page 106.

Memory double word logic

failure at

address

, read

value

expecting

value

Memory odd/even logic

failure at

address

, read

value

expecting

value

Memory write/read failure

at address, read

value

expecting

value

Memory tests terminated by

keystroke.

POST memory test terminated by
pressing the spacebar.

Information only.

No boot device available

Faulty or missing optical/diskette
drive subsystem, hard drive, or hard-
drive subsystem, or no boot disk in
drive A.

Use a bootable diskette, CD, or hard
drive. If the problem persists, see
"Troubleshooting a Diskette Drive" on
page 108, "T
roubleshooting an Optical
Drive" on page 109, and
"Troubleshooting a Hard Drive" on
page 110. See "Using the System Setup
Program" on page 31 for information
about setting the order of boot devices.

Table 1-8.

System Messages (continued)

Message

Causes

Corrective Actions