Dell PowerEdge 6950 User Manual

Page 29

background image

About Your System

29

This system supports only

Opteron 8000 series

processors.

Microprocessor(s) is not supported by
the system.

Install a supported microprocessor or
microprocessor combination. See
"Installing a Processor" on page 64.

Time-of-day clock stopped

Faulty battery or faulty chip.

See "Troubleshooting the System
Battery" on page 104.

Time-of-day not set -

please run SETUP program

Incorrect Time or Date settings; faulty
system battery.

Check the Time and Date settings. See
"Using the System Setup Program" on
page 31. If the problem persists, r
eplace
the system battery. See "System Battery"
on page 78.

Timer chip counter 2

failed

Faulty system board.

See "Getting Help" on page 129.

Unsupported CPU

combination

Unsupported CPU stepping

detected

Microprocessor(s) is not supported by
the system.

Install a supported microprocessor or
microprocessor combination. See
"Installing a Processor" on page 64.

Utility partition not

available

The key was pressed during
POST, but no utility partition exists
on the boot hard drive.

Create a utility partition on the boot
hard drive. See the CDs that came with
your system.

Warning: Following faulty

DIMMs are disabled:

CPU

n

: DIMM

n

CPU

n

: DIMM

n

Total memory size is

reduced.

Faulty or improperly seated memory
module(s) used by CPUn.

See "Troubleshooting System Memory"
on page 106.

Warning! No microcode

update loaded for

processor

n

Microcode update failed.

Update the BIOS firmware. See "Getting
Help" on page 129.

Warning: One or more

faulty DIMMs found on CPUn

Faulty or improperly seated memory
module(s) used by CPUn.

See "Troubleshooting System Memory"
on page 106.

Warning: The installed

memory configuration is

not optimal. For more

information on valid

memory configurations,

please see the system

documentation on the

technical support web

site.

Invalid memory configuration. The
system will run but with reduced
functionality.

Ensure that the memory modules are
installed in a valid configuration. See
"General Memory Module Installation
Guidelines" on page 58. If the problem
persists, see "Troubleshooting System
Memory" on page 106.

Table 1-8.

System Messages (continued)

Message

Causes

Corrective Actions