Attempting to update

Remote Configuration.

Please wait...

Remote Configuration request has
been detected and is being processed.

Wait until the process is complete.

BIOS Update Attempt

Failed!

Remote BIOS update attempt failed. Retry the BIOS update. If problem

persists, see "Getting Help" on page 129.

Caution! NVRAM_CLR jumper

is installed on system

board.

NVRAM_CLR jumper is installed.
CMOS has been cleared.

Remove the NVRAM_CLR jumper. See
Figure 6-1 for jumper locations.

Diskette drive

n

seek

failure

Incorrect configuration settings in the
System Setup program.

Run the System Setup program to
correct the settings. See "Using the
System Setup Program" on page 31.

Faulty or improperly installed diskette
drive.

Replace the diskette. If the problem
persists, see "Troubleshooting a Diskette
Drive" on page 108.

Loose diskette drive interface cable, or
loose power cable.

Reseat diskette drive interface cable, or
power cable. See "Troubleshooting a
Diskette Drive" on page 108.

Diskette read failure

Faulty or improperly inserted diskette. Replace the diskette. If the problem

persists, see "Troubleshooting a Diskette
Drive" on page 108.

Diskette subsystem reset

failed

Faulty or improperly installed
diskette.

Replace the diskette. If the problem
persists, see "Troubleshooting a Diskette
Drive" on page 108.

Drive not ready

Diskette missing from or improperly
inserted in diskette drive.

Replace the diskette. If the problem
persists, see "Troubleshooting a Diskette
Drive" on page 108.

Error: Memory failure

detected. Memory size

reduced. Replace the

faulty DIMM as soon as

possible.

Faulty or improperly seated memory
module(s).

See "Troubleshooting System Memory"
on page 106.

Remote configuration

update attempt failed

System unable to process Remote
Configuration request.

Retry Remote Configuration.

Fatal error caused a

system reset: Please check

the system event log for

details.

Fatal system error.

Check the system event log for the
specific cause, then see the appropriate
section in"Troubleshooting Your System"
on page 97.