Dell POWEREDGE 300 User Manual
Page 29

About Your System
29
E1811
HDD ## Rbld
Abrt
The specified hard drive has
experienced a rebuild abort.
See "Troubleshooting a
Hard Drive" on page 144.
If the problem persists,
see your RAID
documentation.
E1812
HDD ##
Removed
The specified hard drive has
been removed from the
system.
Information only.
E1913
CPU &
Firmware
Mismatch
The BMC firmware does not
support the CPU.
Update to the latest BMC
firmware. See the BMC
User’s Guide for more
information on setup and
use of BMC.
E1A12
PCI Rsr
Config
One or all of the PCIe risers
is configured incorrectly,
preventing the system from
powering on.
Reinstall the missing riser
card(s).
E1A12
PCI Rsr
Missing
One or all of the PCIe risers
is missing, preventing the
system from powering on.
Check that all
connections are secure
and correctly positioned.
E1A14
SAS Cable A
SAS cable A is missing or
bad.
Reseat the cable. If the
problem persists, replace
cable.
If the problem persists,
see "Getting Help" on
page 167.
E1A15
SAS Cable B
SAS cable B is missing or
bad.
Reseat the cable. If the
problem persists, replace
cable.
If the problem persists,
see "Getting Help" on
page 167.
Table 1-6.
LCD Status Messages (continued)
Code
Text
Causes
Corrective Actions
book.book Page 29 Sunday, June 21, 2009 5:16 PM