Table 1-6.
LCD Status Messages
Code
Text
Causes
Corrective Actions
N/A
SYSTEM NAME
A 62-character string that
can be defined by the user in
the System Setup program.
The SYSTEM NAME
displays under the following
conditions:
• The system is powered on.
• The power is off and
active errors are displayed.
This message is for
information only.
You can change the
system ID and name in
the System Setup
program. See "Entering
the System Setup
Program" on page 47.
E1000
FAILSAFE,
Call Support
Check the system event log
for critical failure events.
See "Getting Help" on
page 167.
E1114
Temp Ambient
Ambient system
temperature is out of
acceptable range.
See "Troubleshooting
System Cooling
Problems" on page 136.
E1115
Temp Planar
Planar system temperature
is out of acceptable range.
See "Troubleshooting
System Cooling
Problems" on page 136.
E1118
CPU Temp
Interface
The BMC is unable to
determine the CPU(s)
temperature status.
Consequently, the BMC
increases the CPU fan speed
to maximum
as a precautionary measure.
Turn off power to the
system and restart the
system. See "Getting
Help" on page 167.
E1210
CMOS Batt
CMOS battery is missing, or
the voltage is out of
acceptable range.
See "Troubleshooting the
System Battery" on
page 134.