beautypg.com

Power supply indicator – Dell POWEREDGE 1955 User Manual

Page 19

background image

About Your System

19

Power Supply Indicator

Each hot-pluggable power supply has indicators that provide information about power status, fault, and
the presence of AC power (see Figure 1-6). Table 1-5 lists the power supply indicator codes.

NOTE:

Only 2100-W power supply modules are supported on your system. The 2100-W power supply modules

require 180–240 V input from a PDU capable of providing AC current up to 29.2 A at 180 V input. If the power supply
modules are plugged into 110-V electrical outlets, the system will not power up.

Table 1-4.

Back-Panel Features and Indicators

Component

Indicator Description

Power supply modules

Provide information about power status (see "Power Supply Indicator Codes" on
page 20).

Fan modules

Provide information about status of the system fans (see "Fan Module Indicators"
on page 21).

KVM module

Provides information about the KVM module (see "KVM Modules" on page 22).

DRAC/MC module

Provides information about system status, system management status, and port
status (see "DRAC/MC Module" on page 26).

PowerConnect™ 5316M
Ethernet switch module

Provides information about the 10/100/1000 BASE-T network status (see
"PowerConnect 5316M Ethernet Switch Module" on page 29).

Fibre Channel pass-through
module

Provides information about the Fibre Channel network status (see "Fibre
Channel Pass-Through Module" on page 31).

Fibre Channel switch module

Provides information about the Fibre Channel network status (see "Fibre
Channel Switch Module" on page 32).

Infiniband pass-through
module

Provides information about the Infiniband network status (see "Infiniband Pass-
through Module" on page 32).

Gb pass-through module

Provides information about the network status (see "Gb Ethernet Pass-through
Module" on page 33).