beautypg.com

Dell POWEREDGE R610 User Manual

Page 53

background image

About Your System

53

Warning! PSU

mismatch. PSU

redundancy lost.

Check PSU.

A High Output power supply

and an Energy Smart power

supply are installed in the

system at the same time.

Install two High Output or

two Energy Smart power

supplies in the system. You

can also run the system on

one power supply until you

can obtain two power

supplies of the same type.
See "Troubleshooting Power

Supplies."

Warning!

Unsupported

memory

configuration

detected. The

memory

configuration is

not optimal. The

recommended

memory

configuration

is:

Invalid memory

configuration. The system

will run but with reduced

functionality.

Ensure that the memory

modules are installed in a

valid configuration. See

"System Memory." If the

problem persists, see

"Troubleshooting System

Memory."

Write fault

Write fault on

selected drive

Faulty USB device, USB

medium, optical drive

assembly, hard drive, or hard-

drive subsystem.

Replace the USB medium or

USB device. See

"Troubleshooting a USB

Device," "Troubleshooting an

Internal SD Card,"

"Troubleshooting an Optical

Drive," or "Troubleshooting

Hard Drives."

NOTE:

For the full name of an abbreviation or acronym used in this table, see the

"Glossary."

Table 1-2. System Messages

(continued)

Message

Causes

Corrective Actions