beautypg.com

Dell POWEREDGE R610 User Manual

Page 28

background image

28

About Your System

E161C

Power Supply

# (### W)

lost AC

power. Check

PSU cables.

Specified power supply is

attached to the system, but

it has lost its AC input.

Check the AC power

source for the specified

power supply. If the

problem persists, see

"Troubleshooting Power

Supplies."

E1620

Power Supply

# (### W) AC

power error.

Check PSU

cables.

Specified power supply's

AC input is outside of the

allowable range.

Check the AC power

source for the specified

power supply. If the

problem persists, see

"Troubleshooting Power

Supplies."

E1624

Lost power

supply

redundancy.

Check PSU

cables.

The power supply

subsystem is no longer

redundant. If the remaining

power supply fails, the

system will shut down.

See "Troubleshooting

Power Supplies."

E1626

Power Supply

Mismatch.

PSU1 = ### W,

PSU2 = ### W.

The power supplies in the

system are not the same

wattage.

Ensure that power

supplies with matching

wattage are installed. See

the Technical

Specifications outlined in

your system’s Getting

Started Guide.

E1629

Power

required >

PSU wattage.

Check PSU and

config.

The system configuration

requires more power than

the power supplies can

provide, even with

throttling.

Turn off power to the

system, reduce the

hardware configuration or

install higher-wattage

power supplies, and then

restart the system.

Table 1-1. LCD Status Messages

(continued)

Code

Text

Cause

Corrective Actions