28
About Your System
E161C
Power Supply
# (### W)
lost AC
power. Check
PSU cables.
Specified power supply is
attached to the system, but
it has lost its AC input.
Check the AC power
source for the specified
power supply. If the
problem persists, see
E1620
Power Supply
# (### W) AC
power error.
Check PSU
cables.
Specified power supply's
AC input is outside of the
allowable range.
Check the AC power
source for the specified
power supply. If the
problem persists, see
E1624
Lost power
supply
redundancy.
Check PSU
cables.
The power supply
subsystem is no longer
redundant. If the remaining
power supply fails, the
system will shut down.
E1626
Power Supply
Mismatch.
PSU1 = ### W,
PSU2 = ### W.
The power supplies in the
system are not the same
wattage.
Ensure that power
supplies with matching
wattage are installed. See
the Technical
Specifications outlined in
your system’s Getting
Started Guide.
E1629
Power
required >
PSU wattage.
Check PSU and
config.
The system configuration
requires more power than
the power supplies can
provide, even with
throttling.
Turn off power to the
system, reduce the
hardware configuration or
install higher-wattage
power supplies, and then
restart the system.
Table 1-1. LCD Status Messages
(continued)
Code
Text
Cause
Corrective Actions