Dell POWEREDGE R610 User Manual
Page 43
About Your System
43
Invalid PCIe card
found in the
Internal_Storage
slot!
The system halted because
an invalid PCIe expansion
card is installed in the
dedicated storage controller
slot.
Remove the PCIe expansion
card and install the
integrated storage controller
in the dedicated slot. See
Keyboard
controller
failure
Faulty keyboard controller;
faulty system board
See "Getting Help."
Keyboard data
line failure
Keyboard stuck
key failure
Keyboard cable connector is
improperly connected or the
keyboard is defective.
Reseat the keyboard cable. If
the problem persists, see
Device."
Keyboard fuse has
failed
Overcurrent detected at the
keyboard connector.
See "Getting Help."
Local keyboard
may not work
because all user
accessible USB
ports are
disabled. If
operating
locally, power
cycle the system
and enter system
program to change
settings.
All USB ports are disabled,
preventing keyboard access.
Run the System Setup
program and enable one or
Manufacturing
mode detected
System is in manufacturing
mode.
Reboot to take the system
out of manufacturing mode.
Maximum rank
count exceeded.
The following
DIMM has been
disabled:
x
Invalid memory
configuration. The system
will run but with the
specified DIMM disabled.
Ensure that the memory
modules are installed in a
valid configuration. See
Table 1-2. System Messages
(continued)
Message
Causes
Corrective Actions